Click to enlarge image
|
Caracteristics
- Hi-performance even at hi-temperatue in summer
- Displaying operation state of cooler
- Function of self-checking
- Easy operation
- Function of alarm and emergency light
- Ultra-accuracy temperature control
- IF there needs coolant under 0 oc, use the Ethlene Glycol (EG) mixing proper rate of 50 %
- Designed the drain of remained water in mold (one-touch operation, Patent panding No.21443)
- Designed the drain of remained water for frozen rupture(one-touch operation, Patent panding No.21443)
|
Flow Sheet

Optional Specification
| Model Descriptiom |
BYCH3W |
BYCH5W |
BYCH7.5W |
BYCH10W |
BYCH15W |
BYCH20W |
BYCH30W |
BYCH40W |
BYCH50W |
| Rated Output of
Compressor(kw) |
2.25 |
3.75 |
5.63 |
7.5 |
11.25 |
15 |
22.5 |
30 |
37.5 |
| PUMP Capacity(kw) |
0.4 |
0.4 |
0.75 |
0.75 |
1.5 |
1.5 |
1.5 |
3.75 |
3.75 |
| Outlet Flow-Rate(L/mm) |
180 |
180 |
250 |
250 |
410 |
410 |
410 |
480 |
620 |
| Outlet Pressure(kg/cm2)
|
2~4 |
2~4 |
2~4 |
2~5.5 |
2~5.5 |
2~5.5 |
2~5.5 |
2~5.5 |
2~5.5 |
| Cooling Capacity(kcal/h) |
9,300 |
15,500 |
23,250 |
31,000 |
46,500 |
62,000 |
93,000 |
124,000 |
155,000 |
Dimension
(WxLxH mm) |
1000x550
x900 |
1000x550
x900 |
1200x600
x1100 |
1200x600
x1100 |
1400x750
x1200 |
1400x750
x1200 |
2100x850
x1650 |
2100x850
x1650 |
2100x900
x1700 |
| Weight(kg) |
200 |
260 |
390 |
500 |
610 |
830 |
1,020 |
1,150 |
1,250 |
| Coolant |
R-22 |
| Applicable Injection
M/C(t) |
350 |
350~450 |
450~600 |
600~850 |
850~1300 |
1300~1800 |
1800~2800 |
2800~4200 |
4200~5600 |
Above
specification may be changed without notice for upgrade quality.